input has already played a show that is in a range that overlaps with another
input or sequencer, that other input or sequencer will consider that show as
ʻalready playedʼ too.
You can tell the Br-ANA to reshuffle this list at any time by using the ʻRe-
shuffle Listʼ input action.
K) Reshuffle List:
This input action can only be selected for the ʻClosingʼ edge on an input.
It is used in conjunction with the ʻSequential from Listʼ and ʻRandom from
Listʼ Input Actions to reset the ʻalready playedʼ flags for a range of shows.
The range can be as short as two shows up to all the shows that are loaded
on the Br-ANA. The two drop downs to the right of the Input Action are used
to select the ʻfirstʼ and ʻlastʼ show have their ʻalready playedʼ flags reset.
L) Analog Limit:
Normally the anlaog outputs will follow the complete range of motion you
programmed in your shows, only limited by the analog endpoints you set on
the Br-ANA ʻminimumʼ and ʻmaximumʼ settings.
This feature can be used if you want to scale the analog outputs to limit
them to a lower level when a switch is thrown. This is most commonly used
to connect the switched ʻthresholdʼ outputs of anemometers used with foun-
tain shows. If the wind level gets to the preset ʻthresholdʼ, the anemometer
ʻclosesʼ this input. This tells the Br-ANA to scale the analog outputs, and
thereby the height that the fountain will squirt the water. When the wind level
drops below the ʻthreshold, the anemometer opens this output and a ʻAnalog
Limitʼ action on the ʻopeningʼ edge of the same input tells the Br-ANA to
scale the outputs to 100%, and return the fountain to normal operation.
Use the drop down to the right of the Input Action to select the desired
scaling value to use. A ʻzeroʼ value sets all of the outputs to the voltage set in
the ʻminimumʼ endpoint column. A value of 100% returns the Br-ANA to nor-
mal operation.
M) Binary Bit:
This Input Action allows you to use as many as four of the trigger inputs
to select and play shows using a binary pattern of bits. This allows you to se-
lect and play up to 15 shows through the Optically Isolated Trigger Inputs. It
is often used with our Kp-200 keypads.
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485
Br-ANA Manual / December 18, 2012 10:21 AM / page 51 of 60