time is still about 5 seconds. The time the output dwells at each extreme is
about one second.
U) Set Minimum, Maximum and Forced using Keypad:
This is the easiest way to adjust the endpoints of the analog outputs to
prevent a mechanical movement from over traveling. The normal range of
the outputs is 0 to 10 volts DC. If your analog movement is hitting the ends
of travel, you can reduce this range until it doesnʼt hit the mechanical ends of
travel.
Selecting his command redraws the left side of the screen. The drawing
shows the numeric keypad found on most keyboards. The ʻarrowʼ points to
the output which has been selected. You can select a different output by
pressing the ʻN) Nextʼ or ʻL) Lastʼ commands.
Use the ʻ1ʼ, ʻ4ʼ and ʻ7ʼ keys to adjust the ʻminimumʼ position the for the se-
lected analog output. This sets the voltage that will be sent out from the Br-
ANA when you give it a ʻzeroʼ position command through the DMX-512 or
AutoDownload file. The default analog output (when set to 0/0h) is 0 vdc.
Gilderfluke & Co., Inc. - BR-ANA Analog Card - version 4.10 - copyright 2012 DCM
Shows: 8, Ch: 123 @___0, ADL: AutoDownload_Filename
Serial Address- __0
__1 Show_FileName.sho looping @ frame ____1363
inputs: a/green: Y | b/red: Y MSB E minimum maximum "forced" PowerOn
c/blue: Y | d/white: Y address I scale scale position default
minimum maximum "forced" 0 (0) |_|____0__|__255__|_______|____0__|
adjust--> scale scale position-> 1 (1) |_|____0__|__255__|_______|____0__|
|-----------------------| 2 (2) |_|____0__|__255__|_______|____0__|
Up--> | 7 | 8 | 9 | 3 (3) |_|____0__|__255__|_______|____0__|
|-----------------------| 4 (4) |_|____0__|__255__|_______|____0__|
middle--> | 4 | 5 | 6 | 5 (5) |_|____0__|__255__|_______|____0__|
|-----------------------| 6 (6) |_|____0__|__255__|_______|____0__|
Down--> | 1 | 2 | 3 | 7 (7) |_|____0__|__255__|_______|____0__|
|-----------------------| 8 (8) |_|____0__|__255__|_______|____0__|
9 (9) |_|____0__|__255__|_______|____0__|
10 (A) |_|____0__|__255__|_______|____0__|
11 (B) |_|____0__|__255__|_______|____0__|
a) toggle Auto force to 0% or 100% 12 (C) |_|____0__|__255__|_______|____0__|
1, 4, 7, -) sets "forced" to 0% 13 (D) |_|____0__|__255__|_______|____0__|
2, 5, 8, +) sets "forced" to 100% 14 (E) |_|____0__|__255__|_______|____0__|
Hit <CR> to save, <Esc> to bail out 15 (F) |_|____0__|__255__|_______|____0__|
n) Next, l) Last, i) info, o) def., p) looP, h) Halt, r) save, v) Verify, x) Xit
Command-
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485
Br-ANA Manual / December 18, 2012 10:21 AM / page 38 of 60
Vue de la page 37
1 2 ... 33 34 35 36 37 38 39 40 41 42 43 ... 59 60

Commentaires sur ces manuels

Pas de commentaire