Gilderflukeco BR-ANA Analog Output Smart/Dumb Brick Manuel d'utilisateur Page 47

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 60
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 46
Optically Isolated Trigger Input Actions
The following Input Actions are used to start, stop, and generally control the Br-ANA
through its four optically isolated trigger inputs. The optically isolated trigger inputs can
be used as the sole method to control the Br-ANA, or as an adjunct to the Br-ANAʼs
primary serial port.
You set what each of the Trigger Inputs will do on the AutoDownload dialog, (usually)
after you have finished programming all of your shows and are ready to send them to
the Br-ANA.
The Br-ANA has four Trigger Inputs. You can set different Input Actions for the ʻclos-
ing Edgeʼ
11
on the input and the ʻopening Edgeʼ
12
.This allows you to do things like
ʻpauseʼ a show on a closure of an input, and then ʻcontinueʼ it on the opening of the
same input.
Pc•MACs uses the ʻTarget Deviceʼ to know what options are available for the Trigger
Inputs, number of sequencers available, and even the size of the AutoDownload mem-
ory available. It looks this up from the GilderGearList each time you do an AutoDown-
load, so if new features have been added to the Br-ANA since your last AutoDownload,
you will be able to access them.
Some of the Input Actions require you to enter a second or third value from the drop
downs just to their right. Typically these will be a show, or range of shows for the Input
Action to use.
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485
Br-ANA Manual / December 18, 2012 10:21 AM / page 47 of 60
11
The ʻclosing edgeʼ is when current starts flowing through the optically isolated input, which is usually when an attached switch
ʻclosesʼ. The status of all the Trigger Inputs can be seen on the Br-ANAʼs ʻstatusʼ command and ʻmainʼ menu.
12
The ʻopening edgeʼ is when current stops flowing through the optically isolated input, which is usually when an attached switch
ʻopensʼ. The status of all the Trigger Inputs can be seen on the Br-ANAʼs ʻstatusʼ command and ʻmainʼ menu.
Vue de la page 46
1 2 ... 42 43 44 45 46 47 48 49 50 51 52 ... 59 60

Commentaires sur ces manuels

Pas de commentaire