SER-DMX
Sixteen Channel DMX-512 Input Servo Controller
Printed April 17, 2001
A digital device is either on or off, like a light switch. An analog
device can be on, off, or at any point in between. A common
example of an analog device is a lamp dimmer. In animation,
analog movements give animated figures the fluid, lifelike ap-
pearance needed to bring a figure to life. This is because most
living things are analog too.
GILDERFLUKE & CO.205 SOUTH FLOWER STREET BURBANK, CALIFORNIA 91502 818/840-9484 800/776-5972 FAX 818/840-9485
E
AST COAST /FLORIDA OFFICE 7041 GRAND NATIONAL DRIVE SUITE 128d ORLANDO , FL. 32819 407/354-5954 FAX 407/354-5955
i of iii
Vue de la page 0
1 2 3 4 5 6 ... 25 26

Résumé du contenu

Page 1 - Printed April 17, 2001

SER-DMXSixteen Channel DMX-512 Input Servo ControllerPrinted April 17, 2001A digital device is either on or off, like a light switch. An analogdevice

Page 2 - This page left blank

D) ServoMotor Power: This screw terminal is used to attach the powersupply that will be running the ServoMotors. The voltage output canbe anywhere fro

Page 3

I) Feed Forward and Feed Backwards: These connectors on the sidesof the SER-DMX are used to connect adjacent SER-DMXs. These con-nectors should not b

Page 4

Serial Port Commands:The following commands are used to communicate with SER-DMXsand just about any other piece of equipment manufactured by Gilderf

Page 5 - Overview, continued:

you are attached to the right serial port. The easiest way to do this is to dis-connect the SER-DMX and short between the Tx data out and Rx data inpi

Page 6

SER-DMX Configuration:To enter the configuration mode you need to type the following.The (address) is replaced by the HEX value set on the ADDRESS s

Page 7

In this case the value scale being used is Hex:-Gilderfluke & Company - Sixteen Channel Servo Controller - ver1.04 - c1999 DCM-a) card serial addr

Page 8 - ONE STOP BIT

In this case the value scale being used is decimal:-Gilderfluke & Company - Sixteen Channel Servo Controller - ver1.04 - c1999 DCM-a) card serial

Page 9

If you have selected twelve bits resolution for the outputs, then thevalues will be displayed as follows. Note that addresses that can’t be usedfor t

Page 10

the Eprom has been protected and warn you that you can no longer makeany changes. Configuration changes can be re-enabled at any time bymoving the jum

Page 11

for storing the least significant four bits of the next two twelve bit reso-lution channels. Any twelve bit resolution channel that is addressedat an

Page 12 - Serial Port Commands:

This page left blankGILDERFLUKE & CO .• 205 SOUTH FLOWER STREET • BURBANK , CALIFORNIA 91502 • 818/840-9484 • 800/776-5972 • FAX 818/840-9485EAST

Page 13

6) 2-1/2 seconds7) 5 seconds8) 7.5 seconds9) 10 secondsIf any output crosses or reaches the level it is being commandedto, it will drop out of Ease-In

Page 14 - SER-DMX Configuration:

value), ‘4’ (set the value to 50%), and ‘1’ (decrease the value)keys.b) The ‘Maximum Scale’ endpoint is set using the ‘8’ (increase thevalue), ‘5’ (

Page 15 - 11 of 22

mum position (100%/255/0FFh). 34) Adjust the first endpoint:a) If you set the movement to the minimum position:Use the ‘1’, ‘4’ and ‘7’ keys on your k

Page 16 - 12 of 22

(0%/0/00h). One more press and it will then change to‘n/a’.8) Save your changes: Hitting the <Return>, <Space Bar>or ‘0’ key on your ke

Page 17 - 13 of 22

not in use will allow them to cool and extend their lives.c) All=0: Commanding ALL servos to the zero position willstop all pulses being sent to al

Page 18 - 14 of 22

n) Test & Adjust Next Output:l) Test & Adjust Last Output: These two commands are used to movethe arrow that shows which output you are adjust

Page 19 - 15 of 22

- Decimal to HEXadecimal to ASCII to Percentage -The following chart shows decimal, HEXadecimal, ASCII and a fewpercentage equivalents to aid you w

Page 20 - 16 of 22

Overview, continued ... 1Connections, Jumpers and LEDs on the SER-DMX ...

Page 21 - 17 of 22

This page is blank so that the text starts on a right pageGILDERFLUKE & CO .• 205 SOUTH FLOWER STREET • BURBANK , CALIFORNIA 91502 • 818/840-9484

Page 22 - 18 of 22

Overview, continued:The SER-DMX is used for analog control of remote control-styleServoMotors from a PC•MACs animation control system or anyother de

Page 23 - 19 of 22

narrowed down to restrict the movement to a smaller range.When you adjust either end of travel for your ServoMotors, it willnot affect the other endpo

Page 24 - 20 of 22

Connections, Jumpers and LEDs on the SER-DMX:A) RS-422 Serial Port: This is used to configure the SER-DMX. Althoughthis connector uses an eight positi

Page 25 - 21 of 22

COLOR SIGNAL NAME:LEFT #1 gray - DMX-512 Data Input#2 white (or orange) Signal Ground#3 black - Serial data out from card#4 red + Serial data out from

Page 26 - 22 of 22

line with additional SER-DMXs, Digital Audio Repeaters, Smart BrickBrains and other serially controlled devices. The only requirement isthat each unit