Gilderflukeco DMX-512 Input Servo Motor Controller Manuel d'utilisateur Page 7

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 26
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 6
Connections, Jumpers and LEDs on the SER-DMX:
A) RS-422 Serial Port: This is used to configure the SER-DMX. Although
this connector uses an eight position connector instead of the usual
six, it is still compatible with all of the RS-422 Serial Ports used on
Gilderfluke & Company products. IF you are not using this connec-
tion to bring the DMX-512 into the SER-DMX, then you should use a
six conductor RJ-12 connector when attaching to the serial port.
If you have more than one SER-DMX plugged together side-by-
side, then only one of the cards should have the RS-422 serial data
from your computer attached to it.
The serial data signals from the SER-DMX are brought out on a
eight position RJ-45 (modular telephone style connector). Facing the
end of the cable with the release latch upwards, its pin out is as fol-
lows:
GILDERFLUKE & CO.205 SOUTH FLOWER STREET BURBANK, CALIFORNIA 91502 818/840-9484 800/776-5972 FAX 818/840-9485
E
AST COAST /FLORIDA OFFICE 7041 GRAND NATIONAL DRIVE SUITE 128d ORLANDO , FL. 32819 407/354-5954 FAX 407/354-5955
3 of 22
Vue de la page 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 25 26

Commentaires sur ces manuels

Pas de commentaire