String
Sent
Multiplexer
Selected
AT+++4 <CR>
AT+++5 <CR>
AT+++6 <CR>
AT+++7 <CR>
AT+++8 <CR>
Tx = #4, Rx = #4
Tx = #5, Rx = #5
Tx = #6, Rx = #6
Tx = #7, Rx = #7
Tx = #8, Rx = #8
If more numbers (1-8) are received before the <CR> (0x0D), then you can
choose to route data to more than one of the multiplexed ports a the same
time. The first valid number between 1 and 8 sets the port that will be used of
receiving serial data and routing to the Br-SDC8ʼs ʻConfig./Mux. RS-232 portʼ
(female DE-09) or ʻMux./RS-422ʼ (female Rj-12) ports.
As an example, to send serial data out ports 3, 5, and 7, and listen to port 5
for any serial data which is returned, you would send the string: ʻAT+++537
<CR>ʼ
2) ¼-J6 input bits 0, 1, 2 and 3: A binary pattern of bits presented on these four
input pins will select which multiplexer output is to be used:
Binary
Number
Bit3
Pin #6
(+8)
Bit2
Pin #7
(+4)
Bit1
Pin #8
(+2)
Bit0
Pin #9
(+1)
Multiplexer
Selected
0
1
2
3
4
5
6
7
Off
Off
Off
Off
Tx = ALL, Rx = #1
Off
Off
Off
On
Tx = #1, Rx = #1
Off
Off
On
Off
Tx = #2, Rx = #2
Off
Off
On
On
Tx = #3, Rx = #3
Off
On
Off
Off
Tx = #4, Rx = #4
Off
On
Off
On
Tx = #5, Rx = #5
Off
On
On
Off
Tx = #6, Rx = #6
Off
On
On
On
Tx = #7, Rx = #7