Vue de la page 39
When a Br-SDC8 is in mode0, the string menu is disabled, and the trigger
menu is drawn with all but four commands disabled, with instructions for the multi-
plexer mode:
Which ports are used are selected in one of three ways:
1) ATT+++ commands: Nine ʻspecialʼ strings will be intercepted by the Br-SDC8,
and not passed through to the outputs. When it receives one of these special
strings, instead of passing the string through to the currently selected male DE-
09 plug(s), the Br-SDC8 will use it to select a different port for sending and re-
ceiving serial data.
String
Sent
Multiplexer
Selected
AT+++0 <CR>
AT+++1 <CR>
AT+++2 <CR>
AT+++3 <CR>
Tx = ALL, Rx = #1
Tx = #1, Rx = #1
Tx = #2, Rx = #2
Tx = #3, Rx = #3
- Gilderfluke & Co. - Br-SDC8 Multiport Serial Controller - v2.11 (c) 2014 DCM -
b) 9600 baud, c) clear to default, d) save configuration thru serial, 9) mode 0
Serial Multiplexer (Mode 0) selected:
no strings or shows are available
use J6 bits 0, 1, 2 and 3 of J6 or AT+++ commands to select multiplexer channels
00000000b / 00h / __0