ON# = HPU-Stop Buss disables new show starts
When on, this DipSwitch will keep any shows from being started When
the HPU-Stop buss is active (the HPU-Stop Buss LED is lit) using the ʻShow
Startʼ buttons, even if the ʻShow Startʼ Enables are active.
E) DipSwitch #5: Pause Buss Disables Show Starts
OFF# = Does nothing
ON# = Pause Buss disables new show starts
When on, this DipSwitch will keep any shows from being started When
the Show Pause buss is active (the Show Pause Buss LED is lit) using the
ʻShow Startʼ buttons, even if the ʻShow Startʼ Enables are active.
F) DipSwitch #6: E-Stop Triggers Alarm Output
OFF# = Does nothing
ON# = E-Stop Triggers Alarm Output
When on, when the E-Stop buss is active (the E-Stop Buss LED is lit), the
alarm output will be active too. The alarm output can be attached to a
buzzer, bell or other annunciator to give an audible/visual indication of an er-
ror condition.
G) DipSwitch #7: HPU-Stop Triggers Alarm Output
OFF# = Does nothing
ON# = HPU-Stop Triggers Alarm Output
When on, when the HPU-Stop buss is active (the HPU-Stop Buss LED is
lit), the alarm output will be active too. The alarm output can be attached to a
buzzer, bell or other annunciator to give an audible/visual indication of an er-
ror condition.
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485
Kp-300 Manual / September 4, 2012 4:29 PM / page 35 of 75