Input logging actually takes place at the instant that the Log Belts Button, Re-
mote Log Belts Input, or Show Pause Reset Input are released. The LED next to
the Log Belts Button will light whenever the seat belts are being logged.
G) 24 vdc Power Input to the Kp-300 (v3.0+ Only)
(TWO POSITION SCREW TERMINAL)
Connect the regulated 24 vdc used to power the Kp-300 to these two terminals.
The Kp-300 usually shares power with the Smart Brick System that runs it.
H) Kp-300 Expansion for the Kp-300 (v3.0+ Only)
(16 POSITION RIBBON CABLE CONNECTOR)
The Kp-300 can be used to add up to fifty-six additional optically isolated in-
puts, and up to fourteen additional outputs. It can be factory programmed to con-
trol entry ramps and bridges for motion bases, addition seat belt and occupancy
sensors.
I) ʻAlarmʼ Output (v3.0+ Only)
(TWO POSITION SCREW TERMINAL)
This output provides a 24 vdc signal when DipSwitch #6, DipSwitch #7 or
DipSwitch #8 are switched on to give an alarm on the activation of the E-stop
Buss (E-Stop Buss LED is lit), HPU-Stop Buss (HPU-Stop LED is lit), or Pause
Buss (Show Pause Buss LED is lit). This can be used to drive an audio annuncia-
tor like a Sonalert module directly (up to 24 vdc at 150 ma continuous). Heavier
loads (like an alarm bell) will require a solid state relay between this output and
the bell.
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485
Kp-300 Manual / September 4, 2012 4:29 PM / page 61 of 75